<acronym id="gpyqx"><kbd id="gpyqx"><menu id="gpyqx"></menu></kbd></acronym>

  • <button id="gpyqx"></button>

    1. <dd id="gpyqx"><pre id="gpyqx"></pre></dd>
        1. 高速線纜

          標準協議光模塊

          兼容協議光模塊

          其它種類光器件

          技術支持

          QSFP+轉4*10G SFP+分支型無源電纜

          0.0/5 rating (0 votes)

          Description

          F-tone公司提供QSFP+ 轉 4*10G SFP+ 分支型無源電纜、40G QSFP+ to 4×10G SFP+ Breakout Passive Copper Cable,應用于客戶側40G以太網和10G以太網LAN中,該產品廣泛應用于核心路由器和數據中心場景中。100%完美兼容全系列品牌交換機,路由器,PDH/SDH傳輸設備,EPON,GPON,10G EPON,10G GPON,WDM PON基站等等全系列設備

          QSFP-4SFP-Cables

          Hybrid Passive Copper QSFP+ to 4x SFP+

          40G QSFP+ to 4x 10G SFP+ Direct Attach Passive Copper Cables

          Features

          1. Hybrid cable conforms to the Small Form Factor SFF-8436 and SFF-8431
          2. Support for multi-gigabit data rates :1.0 Gbps - 10.3125 Gbps (per channel)
          3. Maximum aggregate data rate: 41.25 Gbps (4 x 10.3125Gbit/s)
          4. Hybrid cable link length up to 5m (passive limiting)
          5. High-Density QSFP 38-PIN and 4x SFP 20-PIN Connector
          6. Power Supply :+3.3V
          7. Low power consumption: 0.02 W (typ.)
          8. Temperature Range: 0~ 70 °C

          Applications

          40G QSFP+ to 4×10SFP+

          1. 10G/40Gigabit Ethernet
          2. InfiniBand SDR, DDR, QDR
          3. Switches, Routers, and HBAs
          4. Data Centers
          5. Fibre Channel

          STANDARDS COMPLIANCE

          QSFP+

          1. SFF-8436
          2. QDR InfiniBand
          3. QSFP+ MSA
          4. RoHS Compliant

          SFP+

          1. SFF-8431
          2. SFP+ MSA
          3. RoHS Compatible

          Product Description

          The QSFP+ to 4x SFP+ Passive cable assemblies are high performance,cost effective for SFP+ and QSFP+ equipment interconnects . The Hybrid cables are compliant with SFF-8436 and SFF-8431 specifications. It is offer a low power consumption,short reach interconnect applications. The cable each lane is capable of transmitting data at rates up to 10Gb/s ,providing an aggregated rate of 40Gb/s.

          Recommended Operating Conditions

          Parameter

          Symbol

          Min

          Typical

          Max

          Unit

          Storage Ambient Temperature

           

          -40

           

          +85

          °C

          Operating Case Temperature

          Tc

          0

           

          +70

          °C

          Power Supply Voltage

          VCC3

          3.14

          3.3

          3.47

          V

          Power Dissipation

          PD

             

          0.02

          W

          QSFP+ Pin Descriptions


          Pin

          Logic

          Symbol

          Name/Description

          Notes

          1

           

          GND

          Ground

          1

          2

          CML-I

          Tx2n

          Transmitter Inverted Data Input

           

          3

          CML-I

          Tx2p

          Transmitter Non-Inverted Data Input

           

          4

           

          GND

          Ground

          1

          5

          CML-I

          Tx4n

          Transmitter Inverted Data Input

           

          6

          CML-I

          Tx4p

          Transmitter Non-Inverted Data Input

           

          7

           

          GND

          Ground

          1

          8

          LVTTL-I

          ModSelL

          Module Select

           

          9

          LVTTL-I

          ResetL

          Module Reset

           

          10

           

          Vcc Rx

          +3.3V Power Supply Receiver

          2

          11

          LVCMOSI/O

          SCL

          2-wire serial interface clock

           

          12

          LVCMOSI/O

          SDA

          2-wire serial interface data

           

          13

           

          GND

          Ground

          1

          14

          CML-O

          Rx3p

          Receiver Non-Inverted Data Output

           

          15

          CML-O

          Rx3n

          Receiver Inverted Data Output

           

          16

           

          GND

          Ground

          1

          17

          CML-O

          Rx1p

          Receiver Non-Inverted Data Output

           

          18

          CML-O

          Rx1n

          Receiver Inverted Data Output

           

          19

           

          GND

          Ground

          1

          20

           

          GND

          Ground

          1

          21

          CML-O

          Rx2n

          Receiver Inverted Data Output

           

          22

          CML-O

          Rx2p

          Receiver Non-Inverted Data Output

           

          23

           

          GND

          Ground

          1

          24

          CML-O

          Rx4n

          Receiver Inverted Data Output

           

          25

          CML-O

          Rx4p

          Receiver Non-Inverted Data Output

           

          26

           

          GND

          Ground

          1

          27

          LVTTL-O

          ModPrsL

          Module Present

           

          28

          LVTTL-O

          IntL

          Interrupt

           

          29

           

          Vcc Tx

          +3.3V Power supply transmitter

          2

          30

           

          Vcc1

          +3.3V Power supply

          2

          31

          LVTTL-I

          LPMode

          Low Power Mode

           

          32

           

          GND

          Ground

          1

          33

          CML-I

          Tx3p

          Transmitter Non-Inverted Data Input

           

          34

          CML-I

          Tx3n

          Transmitter Inverted Data Input

           

          35

           

          GND

          Ground

          1

          36

          CML-I

          Tx1p

          Transmitter Non-Inverted Data Input

           

          37

          CML-I

          Tx1n

          Transmitter Inverted Data Input

           

          38

           

          GND

          Ground

          1

          Note 1: GND is the symbol for signal and supply (power) common for the QSFP+ module. All are common within the QSFP+ module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal-common ground plane.

          Note 2: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power supplies and shall be applied concurrent- ly. Requirements defined for the host side of the Host Edge Card Connector are listed in Table 6. Recommended host board power supply filtering is shown in Figure 4. Vcc Rx Vcc1 and Vcc Tx may be internally connected with- in the QSFP+ Module module in any combination. The connector pins are each rated for a maximum current of 500 mA.

          SFP+ Pin Descriptions

          Pin

          Logic

          Symbol

          Name/Description

          Notes

          1

           
          VeeT
          Transmitter Ground
           

          2

          LV-TTL-O

          TX_Fault

          N/A

          1

          3

          LV-TTL-I

          TX_DIS

          Transmitter Disable

          2

          4

          LV-TTL-I/O

          SDA

          Tow Wire Serial Data

           

          5

          LV-TTL-I

          SCL

          Tow Wire Serial Clock

           

          6

           

          MOD_DEF0

          Module present, connect to VeeT

           

          7

          LV-TTL-I

          RS0

          N/A

          1

          8

          LV-TTL-O

          LOS

          LOS of Signal

          2

          9

          LV-TTL-I

          RS1

          N/A

          1

          10

           

          VeeR

          Reciever Ground

           

          11

           

          VeeR

          Reciever Ground

           

          12

          CML-O

          RD-

          Reciever Data Inverted

           

          13

          CML-O

          RD+

          Reciever Data Non-Inverted

           

          14

           

          VeeR

          Reciever Ground

           

          15

           

          VccR

          Reciever Supply 3.3V

           

          16

           

          VccT

          Transmitter Supply 3.3V

           

          17

           

          VeeT

          Transmitter Ground

           

          18

          CML-I

          TD+

          Transmitter Data Non-Inverted

           

          19

          CML_I

          TD-

          Transmitter Data Inverted

           

          20

           

          VeeT

          Transmitter Ground

           

          1. Signals not supported in SFP+ Copper pulled-down   to VeeT with 30K ohms resistor

          2. Passive cable assemblies do not support LOS and TX_DIS

          Ordering information

          Part Number

          Product Description

          QSFP-4SFPPC-01

          QSFP+ To 4X SFP+ Direct Attach Cables, 1m (30AWG),0oC ~ +70oC

          QSFP-4SFPPC-03

          QSFP+ To 4X SFP+ Direct Attach Cables, 3m (30AWG),0oC ~ +70oC

          QSFP-4SFPPC-04

          QSFP+ To 4X SFP+ Direct Attach Cables, 5m (28AWG),0oC ~ +70oC

           

          Important Notice

          Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone before they become applicable to any particular order or contract. In accordance with the F-tone policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone or others. Further details are available from any F-tone sales representative.

           

          Search